Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Materials (Basel) ; 17(7)2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38612093

RESUMEN

Properties such as lower melting temperature, good tensile strength, good reliability, and well creep resistance, together with low production cost, make the system Bi-Sn an ideal candidate for fine soldering in applications such as reballing or reflow. The first objective of the work was to determine the thermodynamic quantities of Bi and Sn using the electromotive force measurement method in an electrolytic cell (Gibbs' enthalpies of the mixture, integral molar entropies, and the integral molar excess entropies were determined) at temperatures of 600 K and 903 K. The second objective addressed is the comprehensive characterization of three alloy compositions that were selected and elaborated, namely Bi25Sn75, Bi50Sn50, and Bi75Sn25, and morphological and structural investigations were carried out on them. Optical microscopy and SEM-EDS characterization revealed significant changes in the structure of the elaborated alloys, with all phases being uniformly distributed in the Bi50Sn50 and Bi75Sn25 alloys. These observations were confirmed by XRD and EDP-XRFS analyses. Diffractometric analysis reveals the prevalence of metallic Bi and traces of Sn, the formation of the Sn0.3Bi0.7, Sn0.95Bi0.05 compounds, and SnO and SnO2 phases.

2.
Materials (Basel) ; 16(6)2023 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-36984335

RESUMEN

Titanium and its based alloys are frequently selected for designing biomedical implants and it is thus necessary to study as detailed as possible their corrosion behavior in biological solutions, such as those in the human body environment. In this paper, with the use of molecular orbital calculation, we designed and developed alloys in the Ti-19Mo-xW system (x = 7, 8, 9, and 10 wt%) and investigated the influence of different contents of tungsten on the behavior of Ti-19Mo-xW alloy samples following corrosion in simulated body fluid (SBF). The values of Bo¯ (bond order) and Md¯ (the metal-orbital energy level) were calculated for each alloy and correlations were established between Bo¯ and the content of tungsten. It was found that with the increase in tungsten content, the value of Bo¯ increases. Regarding the values of the corrosion resistance in SBF that resulted from the investigated alloys, the Ti19Mo7W alloy is distinguished by the lowest value of the corrosion current density and the lowest corrosion rate.

3.
J Environ Manage ; 331: 117260, 2023 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-36681029

RESUMEN

The scope of this study consists of setting up of an integrated cost-effective sampling & laboratory analyses procedure which delineates sampling, sub-sampling and analytical uncertainties in case of fine-grained extractive waste deposits. This procedure is designed to support the decision makers towards fine-grained waste deposits upcycling and land reclamation. This procedure consists of a balanced replicated sampling design (BRSD) coupled with a three split levels ANOVA data processing. The paper provides the readership with the mathematical backgrounds of the three split level ANOVA analysis (3L-ANOVA) and an Excel algorithm for its implementation. Also, the paper presents an example of implementation of the developed methods in the case of a Romanian iron ore tailings (IOT) old pond. The findings of the paper consist of: a) argues, based on OM, SEM-EDS, XRFS and XRD observations, that classical TOS is ineffective for fine-grained waste deposits; b) BRSD in conjunction with 3L-ANOVA analysis is the only approach fit for reliable characterization of the fine-grained stockpiles; c) sampling uncertainty is the critical factor of the uncertainty budget of the analyte concentration; d) Lilliefors approach is adequate for the hypothesis testing where or not the measurand is normal distributed; e) The outcomes of the BRDSD&3L-ANOVA investigations carried on Teliuc tailings, estimated at circa 5.5* 106 m3, consist mainly of mineral quantification at lot level i.e. quartz ∼54% (±7%), hematite ∼15% (±3%), calcite ∼11% (±3%), MgO 3% (±1%), Al2O3 9% (±2%). The concentrations of some CRMs like Ti, V, Ba, Y, W were found at ACE limits and their associated relative expanded uncertainties overpass 50%. Thus, the expanded uncertainties clearly depict the reliability of acquired data for the decision makers regarding waste valorization. f) The IOT into Teliuc can be upcycled as minerals for cement and ceramic industries as well as for geopolymer manufacture. Also, IOT can be downcycles as filler in road construction and mine closure. Finally, the Teliuc yard can be rehabilitated with zero-waste left behind. The data exactness provided by this procedure can be increased to any desirable level through increasing the number of collected items, but the cost of sampling and analyses increases proportionally. In such circumstances, the posted approach can be tailored at the stakeholder request as to safely underpin the decision to turn finegrained by-products into valuable secondary resources, facilitating a greater circularity of the mining industry.


Asunto(s)
Compuestos de Hierro , Estanques , Rumanía , Reproducibilidad de los Resultados , Minerales/análisis
4.
Materials (Basel) ; 15(23)2022 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-36500191

RESUMEN

Additive manufacturing (AM) is an important technology that led to a high evolution in the manufacture of personalized implants adapted to the anatomical requirements of patients. Due to a worldwide graft shortage, synthetic scaffolds must be developed. Regarding this aspect, biodegradable materials such as magnesium and its alloys are a possible solution because the second surgery for implant removal is eliminated. Magnesium (Mg) exhibits mechanical properties, which are similar to human bone, biodegradability in human fluids, high biocompatibility, and increased ability to stimulate new bone formation. A current research trend consists of Mg-based scaffold design and manufacture using AM technologies. This review presents the importance of biodegradable implants in treating bone defects, the most used AM methods to produce Mg scaffolds based on powder metallurgy, AM-manufactured implants properties, and in vitro and in vivo analysis. Scaffold properties such as biodegradation, densification, mechanical properties, microstructure, and biocompatibility are presented with examples extracted from the recent literature. The challenges for AM-produced Mg implants by taking into account the available literature are also discussed.

5.
Materials (Basel) ; 12(1)2019 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-30621182

RESUMEN

The ß-Ti alloys have attracted the attention of researchers due to their excellent properties and their remarkable biocompatibility. The present study evaluated the mechanical behavior analysis (hardness, compressive strength, and modulus of elasticity) of the Ti-15Mo-W system. For experimental research, we chose the TiMo15 biocompatible alloy as a starting material. In order to improve the mechanical properties, we added tungsten amounts of 3.88 to 12.20 wt.% and analyzed the results obtained. The successive melting of the samples was done using a vacuum arc furnace in a copper crucible cooled with water. Following micro-structural investigations, we found this alloy possessed a homogeneous structure and showed ß-phase predominance. The investigated alloys have good mechanical properties-the mean Vickers micro-hardness values are between 251 to 321 HV, the compressive strength values range from 717 to 921 MPa, and the modulus of elasticity is between 17.86 and 45.35 GPa. These results are compatible to the requirements of a metallic material for medical applications as artificial implant devices.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...